Footage of Zoomerang’s first operating day at Visionland in Alabama, filmed by one of the contractors who rebuilt the ride. A fault shows at the end of the video.
During commissioning at Visionland the electrical contractor found an intermittent fault in the PLC circuit for the proximity switch that reports the second lift’s chain as up. The PLC will not start a cycle unless that chain is up, ready to drive the train.
On the ride’s first day the fault struck mid-cycle. The train dropped from the first lift and ran forward through the inversions, but when the PLC called for the second lift’s chain drive the chain was not up, so the ride faulted and the train stopped in the second lift’s brakes. The passengers were let out at the emergency unload platform, and the train was winched up the lift and hooked onto the chain.
As the winch cable was wound back up it swung past the proximity sensor that tells the PLC the train is at the top. The lift released the train halfway up, and it ran back down without the speed to reach the station and stalled in the cobra roll. The crew spent about eleven hours on the cobra roll in the Alabama sun getting it out with chain blocks and slings.